bgn-durchfluss.png: Full Metal Variable Area Flow Meter / Counter BGN

Full Metal Variable Area Flow Meter / Counter BGN

For liquids and gases

Measuring / switching range:

0.5 - 5 ... 13 000 - 130 000 l/h water
0.015 - 0.15 ... 240 - 2400 Nm³/h air
Connection: flange DN15 ... DN150, ANSI ¾ ... 6"
Material: stainless steel 1.4404, PTFE-lining, Hastelloy®
pmax: PN40 (16) bar
tmax: 350°C
Accuracy: ±1.6 % of full scale (Gases: ±2 % of full scale)
Options: contacts, analogue output, totaliser, Hart®, Profibus® PA, ATEX
Protection:
IP65 (aluminium housing)
IP67 (stainless steel housing)
Explosion protection: BVS 03 ATEX H/B 112

Datasheet

application/pdf; charset=binary

bgn-gb-flow

358 KB

Operating Instructions

application/pdf; charset=binary

BGN - Operating Instructions

2,4 MB

Miscellaneous

application/pdf; charset=binary

General Safety Instructions

190 KB

Approvals

application/pdf; charset=binary

PTB00ATEX2048X

II 1G Ex ia IIC T6...T1 Ga
II 2G Ex ia IIC T6...T1 Gb

3,8 MB
application/pdf; charset=binary

PTB00ATEX2049X

II 1G Ex ia IIC T6...T1 Ga
II 2 G Ex ia IIC T6...T1 Gb

3,0 MB
application/pdf; charset=binary

PTB99ATEX2128X

II 2G Ex ia IIC T6...T1 Gb

812 KB
application/pdf; charset=binary

PTB99ATEX2219X

II 1G Ex ia IIC T6...T1 Ga
II 2G Ex ia IIC T6...T1 Gb

1,1 MB
application/pdf; charset=binary

ZELM03ATEX0128X

II 1D Ex iaD 20 T...°C

1,3 MB
application/pdf; charset=binary

BVS 03 ATEX H/B 112

Ignition Hazard Assessment

87 KB
application/pdf; charset=binary

IECEx BVS 16.0072

Ex ia IIC T6 Gb

514 KB
application/pdf; charset=binary

PESO P568580

Ex ia IIC T6 Gb

102 KB
application/pdf; charset=binary

DMT 00 ATEX E 075

Transmitter ES, ES-PPA, ES-FF

2,4 MB

Functions

The fluid flows from bottom to top through the meter tube of the flowmeter. The float is lifted until an annular gap between the meter ring and the cone-shaped float is produced which corresponds to the flow. The forces acting on the float are in equilibrium. The forces that are mainly acting on the float comprise buoyancy according to the principle of Archimedes, the flow force of the medium and the weight force. Each position of the float corresponds to a flow value measured during calibration, which is transferred to a scale. The BGN variable area flowmeter consists of a meter tube with connections, a meter ring, and a conical float. By means of a magnet, the position of the float is transferred to an encapsulated follow magnet, which has been fitted to a pointer axle. The position of a second annular follow magnet fitted on the pointer axle is transferred to the scale by means of the pointer.

Other Members of the KOBOLD group

Products by Keyword
KOBOLD Instruments Inc.

1801 Parkway View Drive
15205 Pittsburgh PA
United States of America

Please activate JavaScript

Cookies & Features

This website uses cookies to provide content and features. Details of the technologies used can be found in our privacy policy.

Essential Cookies

Session data such as language selection or spam protection - you can't do without it.

Google Services

Some pages on this website load content from Google Maps and YouTube.

loading
loading