KOBOLD Instruments Inc • 1801 Parkway View Drive • 15205 Pittsburgh, PA • Tel: +1 412 788 2830 • E-mail: 请激活Java脚本 • visit koboldusa.com

hpc-durchfluss.png: 科里奥利质量流量计 HPC

科里奥利质量流量计 HPC

低流量应用
 

 

测量范围:0 - 20kg /h…0 - 50kg /h
连接:1 / 2“NPT内螺纹,G / 2外螺纹,Gyrolok®/Swagelok®6/8/10/12 mm
材料:
测量管不锈钢1.4571
流体不锈钢1.4404
铝,钢二次安全壳
pmax: PN400
耐温:-40…+ 180°C
准确性:
±0.1%读数±零点稳定 液体
±0.5%读数±零点稳定 气体
±0.005 g/cm³ 密度
变送器:
ATEX, IECEx认证
模拟(HART®),二进制,脉冲,状态输出
特点: 抗振动,非常坚固的流体,可变的外壳和安装


vibration resistant, very robust flow body, variable housing and mounting concept

数据表

application/pdf; charset=binary

hpc-gb-flow

456 KB

操作說明

application/pdf; charset=binary

Coriolis HPC - Operating Instructions

4,6 MB
application/pdf; charset=binary

HPC-Ex - Operating Instructions

1,8 MB

杂项

application/pdf; charset=binary

General Safety Instructions

214 KB
application/pdf; charset=binary

HPC-GB-Flyer

352 KB

审批

application/pdf; charset=binary

IECEx CML 19.0025X

Standard connection:
Ex ia IIC T4 Ga
Ex ia IIIC T135°C Da
Tamb = -40°C to +60°C

High temperature connection:
Ex ia IIC T4..T2 Ga
Ex ia IIIC T135°C Da
Ex ia IIIC T190°C/T240°C Db
Tamb = -40°C to +60°C

1,0 MB
application/pdf; charset=binary

CML 19ATEX2096EX

Standard connection:
II 1 G
II 1 D
Ex ia IIC T4 Ga
Ex ia IIIC T135°C Da
Tamb: -40°C to +60°C

High temperature connection:
II 1 G
II 1 D
II 2 D
Ex ia IIC T4..T2 Ga
Ex ia IIIC T135°C Da
Ex ia IIIC T190°C/T240°C Db
Tamb: -40°C to +60°C

124 KB
application/pdf; charset=binary

IECExBVS210069X (UMC4-RM) IECEx

Ex ec [ia Ga] IIC T6-T3 Gc

532 KB
application/pdf; charset=binary

19K4BO-0509X (HPC) KTL

Ex ia IIC T4...T2

19-KA4BO-0510X (HPC) KTL
Ex ia IIIC T135 °C

19-KA4BO-0512X (HPC) KTL
Ex ia IIIC T190 °C/T240 °C

1,2 MB
application/pdf; charset=binary

12-KB4B0-0117X (UMC4) KTL

Ex d [ia] IIC T4-T3

582 KB

下载

video/mp4; charset=binary

HPC - Promotional Video

125,4 MB

Function

The coriolis mass flowmeter HPC works according to the coriolis principle. Mass flow, density and temperature are being measured simultaneously. The volume flow can be calculated from these measurements. HPC mass flow sensors are only available with remote transmitter.

For the measurement of very small flow rates it is common practice to use single pipe coriolis flowmeters. However, with the use of just one measuring pipe the influence of external interferences increases dramatically, often necessitating a costly decoupling. The HPC uses a dual bent pipe measuring system. Furthermore, the sensor coils are not mounted on the measuring pipes anymore but between the pipes. This provides the sensor with a significantly noise-reduced and predictable dynamic behavior, capable of working at higher frequencies, thus further decoupling the sensor measurement from external vibrations.
With these characteristics the HPC coriolis sensor is therefore not only extremely accurate, but also particularly resistant against external interferences. The sensor is therefore very suited for very low flow measurements for all applications for nearly all liquids.

科宝集团工厂

产品关键词
KOBOLD Instruments Inc.

1801 Parkway View Drive
15205 Pittsburgh PA
美國

请激活Java脚本

Cookies & Features

This website uses cookies to provide content and features. Details of the technologies used can be found in our privacy policy.

Essential Cookies

Session data such as language selection or spam protection - you can't do without it.

Statistics

Hosted on this server in Germany: Provides feedback for us and better content for you.

Google Services

Integration of Google Maps for maps, YouTube for some of our videos and Google Tag Manager for our marketing.

loading